Suto Itec Logo 20 Years Yellow Final
Home Case Studies Flow Monitoring Ensures Optimum Compressor Performance

Spotting Compressor Efficiency Loss in Real Time

In the Cosmetic Manufacturing Industry

Compressor Efficiency Monitoring 1 Min 1200x1200
Applications Icon

Application

Real-time air compressor performance monitoring

Applications Icon

Goal

Ensure optimum compressor performance and reduce energy consumption

Applications Icon

Customer

L’Oréal Indonesia

Applications Icon

Sector

Manufacturing of cosmetic products

Overview and Challenges

1. Overview

Rotary screw air compressors are the most commonly used compressor types in the manufacturing industry. They are known for their higher energy efficiency and provide a cleaner air quality compared to piston-type compressors. However, routine maintenance is needed to ensure continuous performance at a high level of efficiency.

2. Challenge of the Customer

Compressed air systems were identified as a key area for improving energy efficiency and reducing CO₂ emissions. However, without real-time monitoring, it was difficult to determine how efficiently the compressors were operating.

In addition, performance degradation can occur over time and remain unnoticed. As a result, issues such as clogged filters, pressure losses, and rising temperatures may increase energy consumption. Therefore, L’Oréal Indonesia needed a reliable solution to detect problems early and support proactive maintenance.

Solution and Implementation

3. Solution and Implementation

L’Oréal Indonesia has been working tirelessly to meet the L’Oréal Group’s global commitment to operate their factory’s energy efficient and to reduce their CO2 emissions.

The compressed air system, and especially the air compressors, have been identified as one of the greatest potentials within their energy efficiency and CO2 reduction program. To get a picture of how much energy the air compressors were consuming and how efficient they were operating, PT. Hebron Perkasa Mandiri began to install SUTO iTEC S430 Wet Air Flow Meter to monitor the air delivery of the compressors.

To log the flow and consumption data, they used the SUTO iTEC S331 Data logger to connect multiple flow meters to a centralized system. Furthermore, the S331’s integrated Ethernet output allowed them to send the real-time data to the centralized monitoring system.

Results and Conclusion

4. Results

After more than a year of logging the data, the installed S430 Compressed Air Flow Meters delivered precise and seamless real-time data about the use of the compressed air and the efficiency of the monitored compressors. This data helped the operators to know exactly when maintenance needed to be carried out on the compressors.

For example, the S430 Flow Meters reported a 5% drop of flow at one of the compressors. By recognizing this, the operator was able to immediately investigate on the root cause. It was found that the inlet filter mats were clogged and the compressor was not operating efficiently anymore. After replacing the filter mats, the compressor’s output went up again and the normal operation continued. This saved energy and would not have been recognized without a real-time monitoring system.

Suto Icon Alarm

5% Flow Alert

A drop in compressor output was detected immediately through real-time monitoring. This helped operators locate the root cause and restore normal operation quickly.

Icon for Monitoring Software

Process Visibility

Real-time data provided clear insight into compressor efficiency and compressed air consumption. This enabled better performance tracking across the system.

Suto Icon Leaf

Lower Energy Use

Early identification of inefficiencies helped prevent unnecessary energy losses. Maintenance actions could be taken before performance deteriorated further.

Exchange Service Icon

Higher Uptime

Continuous monitoring supported condition-based maintenance and improved long-term compressor reliability. This helped reduce unexpected failures and ensured more consistent system performance over time.

5. Conclusion

Real-time monitoring transformed compressor management from reactive maintenance to proactive performance optimization. In addition, continuous visibility into key operating parameters and instant alerts enabled more effective maintenance planning. As a result, L’Oréal Indonesia could support its energy efficiency goals and maintain long-term compressor reliability.

6. Products in Use

The following SUTO iTEC solutions were used to monitor flow, pressure, temperature, and consumption data in real time, enabling early detection of performance degradation and supporting optimum compressor efficiency.

Optimize Compressor Performance with Real-Time Monitoring

Real-time monitoring of compressor performance helps manufacturers improve energy efficiency and reduce operating costs. Furthermore, continuous visibility into flow, pressure, temperature, and consumption data enables early detection of system degradation. As a result, operators can plan maintenance more effectively and maintain optimum compressor performance.

Reduce energy losses, improve system reliability, and maximize compressor efficiency with SUTO iTEC real-time monitoring solutions.

SUTO iTEC- Contact