This Knowledge Base provides clear answers about compressed air monitoring and SUTO iTEC products. Topics include installation, choosing the right instruments, and solving common issues. We update this section regularly with new content. If you cannot find the information you need, please contact us.

Troubleshooting & Maintenance (2)

Incorrect flow readings can be caused by wrong software settings, sensor contamination or moisture in the system. Regular checks help restore measurement accuracy.

Possible causes:
  • The pipe diameter or measuring range may be incorrectly set in the software.
  • Moisture or liquid water may be entering the sensor, especially in thermal mass models.
  • The sensor could be heavily contaminated with oil or particles.
Solutions:
  • Review the sensor settings in S4C-FS and correct any errors in diameter or flow range.
  • Check the compressed air system’s dew point to ensure no water condensation is reaching the sensor.
  • Inspect and clean the sensor, and make sure filters and dryers are functioning properly upstream.

Fluctuating flow readings are often caused by contaminated gas, turbulent flow or incorrect sensor installation. Stable conditions improve measurement reliability.

Possible causes:
  • The air or gas might be contaminated with moisture, oil, or particles.
  • Turbulent flow caused by nearby elbows, valves, or other obstructions may be affecting readings.
  • The sensor could be loose or not inserted to the correct depth.
Solutions:
  • Inspect filters and dryers upstream of the sensor to ensure clean, dry air.
  • Check for rust, oil, or debris that could be interfering with the sensor element.
  • If possible, move the sensor to a more stable section of the pipe, away from bends or valves.
  • Make sure the sensor is firmly secured at the correct insertion depth and orientation.