S435

S435 VORTEX FLOWMETER FOR CONSIMPTION MEASUREMENT OF STEAM (INLINE SENSOR)

Long-term stable measurement of mass flow and consumption in saturated steam with automatic density compensation.

Right Mark

Cost-efficient sensor solution for steam monitoring

Right Mark

Local display for easy configuration and live values

Right Mark

Temperature sensor with automatic density adjustment

Right Mark

Robust industrial design with high-protection level

Right Mark

Signal Outputs: 4 ... 20 mA; Pulse; Modbus/RTU

Right Mark

Easy installation for pipe sizes of DN40 ... DN300

Right Mark

Signalausgänge: 4 ... 20 mA; Impuls; Modbus/RTU

Right Mark

Installation für Rohrgrößen von DN40 ... DN300

The S435 vortex flowmeter is the ideal choice for measuring steam due to its rugged construction, absence of moving parts and high temperature/pressure resistance.

The S435 vortex flowmeter measures flow and consumption in saturated steam with automatic density compensation. This guarantees continuously accurate results. Parameter settings can be made directly on the flow meter via the user interface (keys and display). The Modbus/RTU interface or the analog output allow the S435 to be connected to a SCADA system.

Please contact us here for an application consultation.

  • Measures saturated steam consumption

MEASUREMENT

Flow
Accuracy1.5 % of reading
Selectable unitsm³/h, m³/min, kg/h, t/h
Measuring rangesee table below
Repeatability0.5 % o.RDG
SensorVortex
Turndown ratio10:1
Consumption
Selectable unitsm³, kg, t

SIGNAL INTERFACE & SUPPLY

Analog output
Signal4 ... 20 mA (4-wire), isolated
Scaling0 ... max flow, freely adjustable
Update rateValue updated ever 1 sec
Frequency output
Measuring range0~5000 Hz
Fieldbus
ProtocolModbus/RTU
Update rateValue updated ever 1 sec
Supply
Voltage supply24VDC

GENERAL DATA

Display
IntegratedLCD display
Material
Process connectionCarbon steel /304/316/316L(Flange/Wafer)
HousingSUS 304
SensorSUS 316
Metal partsSUS 304
Miscellaneous
Electrical connection1/2”-14NPT
Protection classIP65
Process connectionwafer
Weightdepends on pipe size - please enquire if needed
Operating conditions
MediumSaturated steam
Medium temperature-40 ... +250 °C
Operating pressure0 ... 1.6 MPa
(applicable for option 2.5MPa or 4.0MPa)
Ambient temperature-10 ... +60 °C
Ambient humidity< 99 % rH
Storage temperature-10 ... +60 °C
Transport temperature-10 ... +60 °C
Pipe sizesDN25 ... DN300