Why does my flow meter not match the reading of another flow meter in the same line?

by | Oct 8, 2025 | 0 comments

Mismatched flow readings are often caused by leaks, incorrect sensor settings or unsuitable installation points that prevent full flow measurement.

Possible causes:
  • There might be leaks or bypasses between the sensors.
  • One or more sensors might have incorrect scaling or pipe diameter settings.
  • Some sensors might not be measuring the full flow path due to poor installation locations.
Solutions:
  • Check the system for any leakage or open bypass valves.
  • Make sure every sensor has the correct settings for pipe diameter, gas type, and measurement range.
  • Verify that the sensors are installed in locations where they can measure the complete flow in the pipeline.