S030
S030 Electrical Current Transmitter to Measure Compressor Energy Consumption
The digital converter supplies an output of 4 … 20 mA DC in linear proportion to the measured current. It comes with a wide measuring range and high accuracy.
Single Phase Power Measurements
By measuring the current of a symmetric power consumer on one phase, compressed air experts can calculate the power consumption of the compressors without the need of measuring voltage additionally.
This offers an analysis of the compressor and allows the user to identify the efficiency of the system.
Please contact us for further questions and information here.
- Current sensing at compressors for load / unload analysis
- Current sensing for power / energy measurement
- Evaluation of machine operation hours
Single Phase Power Measurements
By measuring the current of a symmetric power consumer on one phase, compressed air experts can calculate the power consumption of the compressors without the need of measuring voltage additionally.This offers an analysis of the compressor and allows judging the efficiency of the system.
MEASUREMENT | |
Strom | |
Genauigkeit | 0,5 % der Lesung + 0,2 % des Bereichs |
SIGNAL INTERFACE & SUPPLY | |
Analog output | |
Signal | 4 ... 20 mA 3-wire |
Scaling | 4 mA = 0A AC, 20 mA = 1000A / 3000 A AC |
Load | Max. 300 Ohm |
Supply | |
Voltage supply | 10 – 32 VDC |
Current consumption | Max. 30 mA |
Data interface | |
Connection | open wire ends / ODU connector |
GENERAL DATA | |
Miscellaneous | |
Protection class | IP67 |
Approvals | CE |
Operating conditions | |
Ambient temperature | 0 ... +80 °C |