S415 OEM
S415 OEM Compact Flow Sensor for Compressed Air and Nitrogen (Inline)
Compact and easy to install flow sensor for monitoring compressed air flow and consumption.

Compact design for point-of-use OEM applications

Affordable flow sensor with flexible installation

No straight pipe section required due to flow conditioner

Smartphone App for remote configuration and online values

Economic flow and consumption metering at low investments

Integrated display for on-site values

Isolated 4... 20 mA & Pulse; Modbus/RTU; M-Bus

G inner thread connection - DN8, DN15, DN20, DN25 or DN32
The compact S415 OEM Compact Flow Sensor is an affordable compressed air flow and consumption measurement solution. The S415 OEM can be installed directly at the point of use where accurate compressed air and nitrogen flow measurement is required. It is designed to be seamlessly integrated into OEM compressed air or nitrogen applications.
Low-Cost Monitoring for OEM Application
The S415 OEM will help you improve the compressed air efficiency in any OEM application, by helping to reduce operating costs and finding optimization potentials. The S415 OEM is best suited to general process work where low-cost and broad monitoring of the compressed air flow is required.
Flexible Installation
With its compact design, the S415 OEM can be easily installed into almost any OEM Application, where machine and process monitoring are needed. Equipped with inner G-thread connections ranging from DN8 (1⁄4”) over DN15 (1⁄2”), DN20 (3⁄4”), DN25 (1”) up to DN32 (1,25”). Making it suited for most typical connection sizes at the point of use.
Integrated Flow Conditioner
The advanced flow conditioner eliminates the requirement of straight inlet piping. The innovative mechanical design reduces the pressure loss to a minimum (<30 hPa), while offering highly accurate measurements in difficult pipe designs.
Wireless Communication Interface
The S415 OEM comes standard with wireless communication interface to help the user quickly and easily check the flow meter readings or adjust the settings via the SUTO flow meter app S4C-FS.
Various Sensor Outputs
The S415 OEM Flow Sensor comes with various sensor outputs, such as 4 … 20 mA, Modbus RTU, M-Bus. With the Modbus/ RTU interface, the S415 can be easily daisy-chained to a Modbus Master device such as our S331 by using an RS-485 splitter (A554 3310) and the M8 to M12 converter cable (A553 0161). Through this method, you can add up to 16 flow meters to the master device.
If there are any special requests, such as custom flow ranges or different gas types, please contact us here.
The S415 OEM flow sensor measures the air and gas consumption directly at the point of use. Thanks to the compact size, it can fit in any application.
MEASUREMENT | |
Flow | |
Accuracy | 3 % o.RDG ±0.3 % FS |
Selectable units | l/min, cfm, kg/h, m3/h |
Measuring range | see table below |
Repeatability | 1 % o.RDG |
Sensor | Thermal mass flow sensor |
Sampling rate | 3/sec |
Turndown ratio | 50:1 |
Response time (t90) | 2 sec |
Consumption | |
Selectable units | m³, ft³, l, kg |
Reference conditions | |
Selectable conditions | 20 °C 1000 mbar (ISO1217) 0 °C 1013 mbar (DIN1343) freely adjustable |
SIGNAL INTERFACE & SUPPLY | |
Analog output | |
Signal | 4 ... 20 mA, isolated |
Scaling | 0 ... max flow |
Load | 250R |
Update rate | 3/sec |
Pulse output | |
Signal | Max 30 V, 200 mA |
Scaling | 1 pulse per consumption unit |
Fieldbus | |
Interface/Protocol | RS-485/Modbus/RTU M-Bus |
Supply | |
Voltage supply | 15 ... 30 VDC |
Current consumption | 120 mA @ 24 VDC |
GENERAL DATA | |
Configuration | |
Wireless | S4C-FS App for mobile phones |
Display | |
Integrated | 4 digit LED |
Material | |
Process connection | Aluminum alloy |
Housing | PC + ABS |
Sensor | Glass coated resistive sensor |
Metal parts | Aluminum alloy |
Miscellaneous | |
Electrical connection | 2 x M8 (4 pole) |
Protection class | IP54 |
Approvals | CE, RoHS, FCC |
Process connection | G-thread |
Weight | 0.45 ... 1.3 kg (depends on model) |
Operating conditions | |
Medium | Air, N2 |
Medium quality | ISO 8573: 4.4.3 or better |
Medium temperature | 0 ... 50 °C |
Medium humidity | < 90 % rH, no condensation |
Operating pressure | 0 ... 10 bar(g) |
Ambient temperature | 0 ... 50 °C |
Ambient humidity | < 95 % rH |
Storage temperature | -30 ... 70 °C |
Transport temperature | -30 ... 70 °C |
Pipe sizes | DN8, DN15, DN20, DN25, DN32 |
MEASURING RANGE | |||||
Process connection | DN8 | DN15 | DN20 | DN25 | DN32 |
Standard range (S) | 250 | 1000 | 2000 | 3500 | 6000 |
Low range (L) | 50 | 200 | 400 | 700 | 1200 |
Stated measuring ranges for S415 OEM under following conditions: Standard flow in air in l/min Reference pressure: 1000 mbar Reference Temperature: +20 °C |
S415 OEM
Manuals
S415 OEM
Leaflets
S401/ S402/ S415/ S418/ S418-V/ S421/ S430/ S450/ S452/ S460 /S461 /S462 – CE & UKCA DECLARATION OF CONFORMITY
CE / UKCA DOC
S415 Firmware: V2.9
Firmware
“S401: INSTALLTION EINES DURCHFLUSSMESSERS UNTER DRUCK”
Personal advice
Would you like to receive more information about products and applications?
Or do you need personal advice? We’re here to help!