S418-V
S418-V Compact Flow Meter for Vacuum Applications (Inline-Sensor)
Compact vacuum flow meter for precise monitoring of performance vacuum pumps.
Compact flow meter for vacuum flow measurements
Pressure sensor for actual vacuum flow measurements
Accurate results thanks to the flow conditioner
Free smartphone app for live values and configuration
Easy and inexpensive process monitoring
Convenient installation and great flexibility
Isolated 4... 20 mA & Pulse; Modbus/ RTU; M-Bus
G inner thread connection: DN8, DN15, DN20, DN25 or DN32
The use of thermal mass flow technology makes the flow meter also resistant with regards to temperature and pressure changes.
Vacuum System Optimization and Reliability
By monitoring the flow, consumption, pressure and temperature at the point of use, the flow meter helps to optimize vacuum system efficiency and discover optimization potentials.
Equipped with an absolute pressure sensor, it does not only show the vacuum pressure, but also shows the actual vacuum flow. These parameters are crucial values in vacuum applications and help operators to ensure their process reliability.
Flexible Installation
The S418-V offers great flexibility at the point of use and can be installed anywhere. With the integrated display the vacuum sensor is available for different pipe sizes DN8, DN15, DN20, DN25 and DN32 (G female thread).
Smartphone App for Configuration and Real-time Data
The Flow Meter is easily configurable through the SUTO S4C-FS App. Real-time data can also be read on the smartphone through the app. This helps to get a fast overview over the actual data and situation.
The more accurate you can monitor gas flow, the more likely you will discover weak points in the process flow, thus ensuring continuity and profitability. Please contact us here to find the best possible configuration for your application.
S418-V is used for performance monitoring of vacuum pumps. Equipped with an absolute pressure sensor, it does not only show the vacuum pressure, but also shows the actual vacuum flow. These parameters are most the critical values in vacuum applications and help operators to ensure their process reliability.
MEASUREMENT | |
Flow | |
Accuracy | 1.5 % of reading ± 0.3 % FS |
Selectable units | m³/h, l/min, cfm, kg/h |
Measuring range | see table on the previous page |
Repeatability | 0.5 % of reading |
Sensor | Thermal mass flow sensor |
Sampling rate | 10 samples / sec |
Turndown ratio | 1:100 |
Response time (t90) | 0.5 sec |
Consumption | |
Selectable units | m³, ft³, l, kg |
Pressure | |
Accuracy | 0.5 % FS |
Selectable units | bar, psi |
Measuring range | 0.01 ... 1.6 bar(a) |
Sensor | Piezo resistive sensor |
Reference conditions | |
Selectable conditions | 20 °C 1000 mbar (ISO1217) |
SIGNAL INTERFACE & SUPPLY | |
Analog output | |
Signal | 4 ... 20 mA (4-wire), isolated |
Scaling | 0 ... max flow, freely adjustable |
Load | max. 250 Ohm |
Update rate | 3/sec |
Pulse output | |
Signal | Switch output, normally open, max. 30 VDC, 200 mA |
Scaling | 1 pulse per consumption unit |
Fieldbus | |
Protocol | Modbus/RTU |
Supply | |
Voltage supply | 15 ... 30 VDC |
Current consumption | 120 mA @ 24 VDC |
Data interface | |
Connection | USB micro |
GENERAL DATA | |
Configuration | |
Wireless | S4C-FS App for mobile phones |
PC Software | S4A PC software for data analyzes |
Display | |
Integrated | 4 digit LED |
Data Logger | |
Storage | 8 Mio. values |
Material | |
Process connection | Aluminum alloy |
Housing | PC + ABS |
Sensor | Ceramic, glass coated |
Metal parts | Aluminum alloy |
Miscellaneous | |
Electrical connection | 2 x M8 (4 pole) |
Protection class | IP54 |
Approvals | CE, RoHS, FCC |
Process connection | G-thread |
Weight | 0.45 ... 1.1 kg (depends on model) |
Operating conditions | |
Medium | Air, N2, O2, CO2 and other gases |
Medium quality | ISO 8573: 4.4.3 or better |
Medium temperature | 0 ... 50 °C |
Medium humidity | < 90 % rH, no condensation |
Operating pressure | Max. 10 bar(g) |
Ambient temperature | 0 ... 50 °C |
Ambient humidity | < 95 % rH |
Storage temperature | -30 ... 70 °C |
Transport temperature | -30 ... 70 °C |
Pipe sizes | DN8, DN15, DN20, DN25 |
MEASURING RANGE | |||||
Process connection | DN8 | DN15 | DN20 | DN25 | Absolute Pressure (mbar) |
Vacuum flow in l/min | 56 | 222 | 444 | 778 | 900 |
63 | 250 | 500 | 875 | 800 | |
71 | 286 | 571 | 1000 | 700 | |
83 | 333 | 667 | 1167 | 600 | |
100 | 400 | 800 | 1400 | 500 | |
125 | 500 | 1000 | 1750 | 400 | |
167 | 557 | 1333 | 2333 | 300 | |
250 | 1000 | 2000 | 3500 | 200 | |
500 | 2000 | 4000 | 7000 | 100 | |
Stated measuring ranges for S418-V under following conditions: Standard flow in air in l/min Reference pressure: 1000 mbar Reference Temperature: +20 °C |
VACUUM SCALES | ||||
bar(a) | inch Hg(g) | kPa(g) | bar(g) | mbar(a) |
1.00 | 0.00 | 0 | 0.00 | 1000 |
0.90 | -2.95 | -10 | -0.10 | 900 |
0.80 | -5.91 | -20 | -0.20 | 800 |
0.70 | -8.86 | -30 | -0.30 | 700 |
0.60 | -11.81 | -40 | -0.40 | 600 |
0.50 | -14.77 | -50 | -0.50 | 500 |
0.40 | -17.72 | -60 | -0.60 | 400 |
0.30 | -20.67 | -70 | -0.70 | 300 |
0.20 | -23.63 | -80 | -0.80 | 200 |
0.10 | -26.58 | -90 | -0.90 | 100 |
0.01 | -29.24 | -99 | -0.99 | 10 |
S418-V
ManualsS418-V
Info sheetsS401/ S402/ S415/ S418/ S418-V/ S421/ S430/ S450/ S452/ S460 /S461 /S462 – CE & UKCA DECLARATION OF CONFORMITY
CE / UKCA DOCS418 / S418-V Firmware: V3.4
FirmwareExisting PCBA 0460 0527 (Lower than 2.1) must be used with FW version lower than V5.0S4C-FS App Android: V2.4.3
SoftwarePersonal advice
Would you like to receive more information about products and applications?
Or do you need personal advice? We’re here to help!