S601
S601 Stationary Compressed Air Purity Monitor for 24/7 Quality Measurement
Permanent 24/7 compressed air quality and purity monitoring according to ISO 8573-1.
All-in-one solution to measure ISO 8573-1 parameters
24/7 compressed air quality and purity monitoring
High-resolution 5" color touch screen
Integrated data Logger for online monitoring
Single compressed air inlet for a convenient setup
Robust metal cabinet for rough industrial applications
Plug & Play operation, no configuration needed
For Compressed Air, Nitrogen N2, Carbon dioxide CO2
The SUTO S601 Compressed Air Purity Monitor permanently measures and monitors compressed air contaminants like Dew Point, Oil Vapor, Particle Concentration and Pressure in real time. In doing so, the S601 brings together state-of-the-art technology in one easy to use package.
24/7 Compressed Air Quality and Purity Monitoring
Product contamination can ruin a business and harm its customers. The typical approach of spot checks and random testing of compressed air systems does not allow businesses to quickly react to contamination events. It also does not provide continual assurance that contamination levels are being kept under control. In the ever-changing world of production, real-time and permanent monitoring is crucial to protect your products’ integrity. The SUTO S601 monitors contaminants, giving businesses piece of mind that its products and customers are protected.
Compliance with the ISO 8573-1 Standard
With the advancement in technology and SUTO´s revolutionary sensors, the S601 is perfectly suited to monitor the air purity parameters in accordance to ISO 8573-1. Particle, dew point and oil vapor contamination are all continuously monitored and stored for later reporting. And this is all done in one single device.
Integrated Data Logger for Data Analysis
The data logging function ensures records are kept intact and stored. Real-time information can be then retrieved from the S601 by SCADA systems via Modbus outputs. The integrated color touch screen display also allows users to view all information locally.
Alarm Indication
Alarm points can be set to trigger if contaminants hit the selected limits. An optional external light or siren can be added to the alarm.
All Measurement Ranges at a glance
- Particle measurement from 0.1 < d ≤ 0.5 µm, 0.5 < d ≤ 1.0 µm, 1.0 < d ≤ 5.0 µm
- Pressure Measurement (0.3 … 1.5 MPa)
- Dew point measurement from -100 to +20°C Td
- Oil vapor measurement from 0,001 bis 5,000 mg/m³
Easy Installation and Connection
The S601 Stationary Compressed Air Purity Monitor is quick and easy to install, just connect the unit to power and the compressed air supplies with a user-friendly 6 mm quick connector. The Robust IP54 wall mountable casing provides high protection in industrial environments.
SUTO Exchange Service
The exchange calibration service eliminates downtime of the S601. It enables users to have a seamless record of their compressed air quality measurements. Get to know more about the SUTO Exchange Service here.
If you have any special request or further question, please contact us here. We are happy to help.
- Permanent measurement and monitoring of compressed air quality in high-tech applications with strict purity requirements, such as medical air, pharmaceuticals, food and beverage, etc.
- Ensuring compressed air quality standards according to ISO 8573-1.
- The robust cabinet makes is well suited for rough industrial applications.
MEASUREMENT | |
Particle concentration | |
Accuracy | Option A1263: 30 ... 70 % von d > 0.1 μm 90 ... 110 % von d ≥ 0.3 μm |
Option A1260: 50 % @ 0.1 < d ≤ 0.15 μm 100 @ d > 0.15 μm |
|
Selectable units | cn/m³, cn/ft³ |
Measuring range | Option A1263: 0.1 < d ≤ 0.5 μm 0.5 < d ≤ 1.0 μm 1.0 < d ≤ 5.0 μm 5.0 μm < d |
Option A1260: 0.3 < d ≤ 0.5 μm 0.5 < d ≤ 1.0 μm 1.0 < d ≤ 5.0 μm 5.0 μm < d |
|
Sensor | Laser optical particle counter |
Sampling rate | 1 min. |
Flow rate | 2.83 l/min |
Pressure Dew Point | |
Accuracy | ± 1 °C Td (0 ... 20 °C Td) ± 2 °C Td (-70 ... 0 °C Td) ± 3 °C Td (-100 ... -70 °C Td) |
Selectable units | °C, °F |
Measuring range | -100 ... +20 °C Td |
Sensor | QCM + Polymer |
Response time (t90) | -20 °C Td -> -60 °C Td = < 240 sec -60 °C Td -> -20°C Td = < 30 sec @ 4 l/min |
Oil vapor | |
Accuracy | 5 % of value +/- 0.003 mg/m³ |
Detection limit | 0.003 mg/m³ |
Resolution | 0.001 mg/m³ |
Selectable units | mg/m³ |
Measuring range | 0.001 ... 5.000 mg/m³ |
Sensor | PID (Photoionisation detector) |
UV lamp lifetime | 1 year or 6000 working hours, whichever comes first |
Sampling rate | 1 sec. |
Pressure | |
Accuracy | 0.5 % FS |
Measuring range | 0.1 ... 1.6 MPa(g) |
Sensor | Piezo resistive sensor |
Temperature | |
Accuracy | ± 0.3 °C |
Measuring range | -30 ... +70 °C |
Sensor | Pt100 |
Reference conditions | |
Selectable conditions | ISO1217 20 °C 1000 mbar |
SIGNAL INTERFACE & SUPPLY | |
Fieldbus | |
Protocol | Modbus/TCP |
Update rate | 1 / sec. |
Alarm output | |
Relay | 2 x Changeover Relay (freely programmable) |
Rating | 230 VAC, 3A |
Power Supply | |
Voltage supply | 100 ... 240 VAC, 50/60 Hz |
Current consumption | 50 VA |
Interface | |
USB | USB Micro with OTG support |
GENERAL DATA | |
Configuration | |
Others | Device comes pre-configured Configuration can be done via on-screen touch |
Display | |
Integrated | Touchscreen, Size: 5“, Resolution: 800 x 480 px |
Data Logger | |
Storage | Up to 3 million recorded data sets (10 channels each) |
Material | |
Process connection | Brass nickel-plated, FKM |
Housing | Sheet steel, powder coated cabinet |
Miscellaneous | |
Electrical connection | AC Clamp Terminals, M12, RJ45 |
Protection class | IP54 (cover lid closed) |
Approvals | CE |
Prozessanschluss | Micro quick connector, full passthrough, male (1.5 m hose with coupling included) |
Weight | 15 kg |
Operating conditions | |
Medium | Compressed Air, Nitrogen Nâ‚‚, Carbon dioxide COâ‚‚ (software setting) |
Medium quality | ISO 8573-1: 4.4.4 or better |
Medium temperature | 0 ... + 40 °C |
Medium humidity | Medium humidity < 40 % rH, no condensation |
Operating pressure | 0.3 ... 1.5 MPa(g) |
Ambient temperature | 0 ... +50 °C |
Ambient humidity | 0 ... 90 % rH |
Storage temperature | -10 ... +70 °C |
Transport temperature | -10 ... +70 °C |
Ensuring Purity and Reliability to ISO 8573-1 Standards
ISO 8573-1 sets global standards for evaluating the purity classes of compressed air, considering particles, water, and oil. Meeting the strict criteria of industries like pharmaceuticals and food requires regular assessment of compressed air quality. The S601 Stationary Compressed Air Quality Monitor is crafted to align with ISO 8573-1 standards, providing a dependable method to assess and guarantee the purity of compressed air. Consistent monitoring with this monitor not only ensures the safety of processes and products but also mitigates production downtime and improves the overall reliability of the system.
Class | Particle Concentration | Pressure Dew Point | Oil Concentration | ||
---|---|---|---|---|---|
cn/m3 | ºC (ºF) | mg/m3 | |||
0.1 < d ≤ 0.5 µm | 0.5 < d ≤ 1.0 µm | 1.0 < d ≤ 5.0 µm | |||
0 | As specified by the equipment user or supplier and more stringent than class 1 | ||||
1 | ≤ 20,000 | ≤ 400 | ≤ 10 | ≤ -70 (94.0) | ≤ 0.01 |
2 | ≤ 400,000 | ≤ 6,000 | ≤ 100 | ≤ -40 (-40.0) | ≤ 0.1 |
3 | undetermined | ≤ 90,000 | ≤ 1,000 | ≤ -20 (-4.0) | ≤ 1 |
4 | undetermined | undetermined | ≤ 10,000 | ≤ +3 (+37.4) | ≤ 5 |
5 | undetermined | undetermined | ≤ 100,000 | ≤ +7 (+45.6) | > 5 |
6 | x | x | x | ≤ +10 (+50.0) | x |